8321 Seymour Hwy
Wichita Falls, Texas 76305

email: sales@wichitatank.com
ph:  940-696-8012
fax: 940-696-8142



Outside Manifold

Rodless Frac Tank

Floor: ¼ " plate with 4" deep " V" in center.
Floor Structure: 12" channel outer runners and 10" channel inner runners with 316" plate formed angle cross members.
Walls: ¼ " plate solid-welded with " V " corrugations on 13 ½ " centers.
Roof: Cambered ¼ " top solid-welded with 4" capped channel outside for support.
Front/Rear: ¼ " plate solid-welded with " V " corrugated steel and 45° corners.
Drain/Fill: 4" suction line with valve on front of tank terminating in sump on side of tank. 8" outside manifold with 4 - 4" couplings with plugs and 8" frac union on ends with caps.
Gel Line: 4" line with valve at front of tank. Line will 45° up at rear.
Man ways: 20" man ways front and curbside rear. Three non-sealing hatches on roof with safety bars.
Tow Latching: Standard 5th wheel kingpin.
Welds: All welds continuous including substructure and cross members.
Axle/Wheels: 22,500# axle with DOT approved braking system and new 11.00 x 22.5 tires on steel wheels.
Access: Front stairway with handrails.
Finish: Interior - blasted and coated with epoxy liner. Exterior - blasted, primed and top coated with polyurethane paint. Floor substructure - undercoated with coal tar epoxy
Testing: Full capacity static water test.
Dimensions: Overall - 45‘2" long, 8‘ 6" wide, 9‘10" tall to top of roof rafters. Capacity - 500bbl

Pictures

Outside Manifold

return to menu

Inside Manifold

Rodless Frac Tank

Floor: ¼ " plate with 4" deep " V" in center.
Floor Structure: 12" channel outer runners and 10" channel inner runners with 316" plate formed angle cross members.
Walls: ¼ " plate solid-welded with " V " corrugations on 13 ½ " centers.
Roof: Cambered ¼ " top solid-welded with 4" capped channel outside for support.
Front/Rear: ¼ " plate solid-welded with " V " corrugated steel and 45° corners.
Drain/Fill: 4" suction line with valve on front of tank terminating in sump on side of tank. 8" interior manifold terminating in sump with 4 - 4" lines through front with flanges and valves installed.
Gel Line: 4" line with valve at front of tank. Line will 45up at rear.
Man ways: 20" man ways front and curbside rear. Three non-sealing hatches on roof with safety bars.
Tow Latching: Standard 5th wheel kingpin.
Welds: All welds continuous including substructure and cross members.
Axle/Wheels: 22,500# axle with DOT approved braking system and new 11.00 x 22.5 tires on steel wheels.
Access: Front stairway with handrails.
Finish: Interior - blasted and coated with epoxy liner. Exterior - blasted, primed and top coated with polyurethane paint. Floor substructure - undercoated with coal tar epoxy
Testing: Full capacity static water test.
Dimensions: Overall - 45‘2" long, 8‘ 6" wide, 9‘10" tall to top of roof rafters. Capacity - 500bbl

Picture

Inside Manifold

return to menu

Slope Top

500bbl Frac Tank

Description
316" A-36 steel floor, side walls and roof sheets
Internal rod bracing
External roof rafters
45° vertical corners
V-bottom floor design for easy maintenance and quick drainage
Solid-welded 12" channel runners with 10" channel cross member floor construction
Solid-welded construction
Standard Features
16" hinged covered openings located on top for ventilation
20" man way on curbside floor and on front
½ " solid piece construction 5th wheel plate with standard kingpin
Rear ladder for roof access
4" gel line controlled with 4" butterfly valve on front
3" fill line on back
4" butterfly rear drain valve with " WTM" extended service access
Full static water test
Options
Interior or exterior manifold
Lighting and Braking System
USDOT approved light and air braking system
Axle and Tires
New axle rated for 22,500# spring suspension for highway use
New 11.00 x 22.5 tires

Picture

Slope Top

return to menu